Pressure Regulator is far superior than Pressure Reducer, as the latter doesn't provide for regulation. As per GDCD code 234, Sample Pressure Regulation shall be achieved by using a staineless steel pressure regulating device located in the system after the sample cooler. It shall be rated for maximum inlet pressure equivalent to that at the sampling point and shall be capable of adjustment for outlet pressures of 1 to 3 bar. We offer Pressure Regulator which provides pressure reduction as well as regulation. This feature is crucial for ensuring steady sample conditions for analysis
FUNCTION : REGULATION, PISTON TYPE
FLUID : WATER
GENERAL : LINE SIZE 1/4” OD
MOUNTING : LINE
CONTROL : WITH A SOCKET SET SCREW WITH LOCK NUT
BODY : SS-316
MATERIAL : DIAPHRAGM SS316 WITH PTFE LINING
SEAT : CARBON FILLED TEFLON
INLET : 1/4” OD
CONNECTION : OUTLET 1/4” OD
INLET PRESSURE : 250 KG/CM2 (MAX.)
SERVICE : OUTLET PRESSURE 0-6 KG/CM2 (MAX.) ADJUSTABLE
TEMPERATURE : 80 DEG.C (MAX)
FLOW : 100 LPH (MAX.)
Pressure Regulators are used for reducing as well as regulating pressure. Forbes Marshall pressure regulator is designed to handle SWAS applications. There are two versions, one is High Pressure Regulator, where the regulation is provided by piston mechanism, while in case of Low Pressure regulator, a spring loaded diaphrgm plays the same function