122,500 Kilograms fuel saved annually through steam and condensate system improvements for a Thai beverage MNC
A leading beverage plant in Phra Nakhon Si Ayutthaya, Thailand, was facing several issues with its steam and condensate system. Float traps at the Bottle Washer lines 4, 5, 6 and 7 were causing low process temperatures, resulting in condensate stalling. Due to this, the trap bypass valve had to be kept open. Electrical pumps were used for condensate recovery across lines 5 and 7, which had issues causing frequent condensate loss through draining. Forbes Marshall conducted a plant study and recommended solutions to improve bottle washer performance and condensate recovery.
Products
Associated Services

Process Optimization

Improving Uptime